Combining the remaining volumes of two compartments containing
the same product
•
Draining of the system (pump, meter, valves, hose, etc.) into a slop
tank while filling the system with a different product
To carry out a Self Loading, the suction side (inlet) of the pump has to be
connected to the depot (additional trailer, storage tank, etc.) while the
outlet of the meter has to be connected to the filling coupling of the tank
truck compartment via the dry hose.
6.11 MultiFlow emergency power supply MF-EPS
(MID version only)
•
In case the supply of the primary current fails during a measurement,
an emergency program is started in the MultiFlow. The measurement
data saved up to this point in time is safeguarded in a non-volatile
memory area (battery-buffered). Once the primary current supply
returns, the measurement must be ended with a printout before
another one can be carried out. In the case of longer power failures it
is also possible to display the quantity delivered at the time of the
interruption via the MF-EPS emergency power supply.
•
If a printout is attempted once the measurement is over with no paper
in the printer, then the "Please insert paper" message is displayed.
Continued operation of the MultiFlow and startup of a further
measurement is blocked until paper has been inserted into the printer
and the printout performed.
•
Any printer malfunctioning is shown through an appropriate message.
The receipt data to be printed out is shown on the display and can be
written down.