MultiFlow  Address and contact details
3.1.4.0.3
Volume limit
M
3
Only for the English version of the program.
Parameter not active in German version.
3.1.4.0.4
OBC summary
M
3
0 (no)
Summary of all orders transmitted by the OBC on
one receipt
W & M Restrictions
No.
Name
Seal
K
Factory
Settings
Meaning
3.1.5
W & M Restriction
3.1.5.1
Parameter List 1
3.1.5.1.1
Volume Resolution
Cal.
1
0
Volume division: Number of post-decimal places on
volume display.
3.1.5.1.2
No. of Discharges
Cal.
1
1
Maximum number of discharges per receipt.
3.1.5.1.3
Minimum Preset
Cal.
1
200
(liters)
Minimum default volume for discharge
(in increments of 200 liters)
3.1.5.1.4
Minimum Layout
Cal.
1
2,3,(11:12),2
5
Minimum requirement from W&M for bill / delivery
receipt
3.1.5.1.5
Price Correction
Cal.
1
1 (yes)
Determines whether the retrospective modification of
prices is permitted with measured products.
3.1.5.1.6
Decimal Separator
Cal.
1
1 (‘,’)
Separator for decimal places: '.' or ','
3.1.5.1.7
Show Additive
Cal.
1
0 (no)
IMPORTANT: Parameter not currently active. See
parameter 3.3.3.3.
3.1.5.1.8
Flushing volume
3.1.5.1.8.1
Flushing product
Mast
er
3
Product index
Definition of product used to flush the measuring
system.
3.1.5.1.8.2
Flushing volume
Mast
er
3
0 (liters)
Specification of the quantity of product used to flush
the measuring system
3.1.5.1.8.3
Min. flushing volume
Cal.
1
0 (liters)
Minimum pre-set quantity after a product change (due
to product contamination) in liters. Specify according
to calibration regulations.
3.1.5.1.8.4
OBC flushing monitor
Mast
er
3
0 (no)
Monitors flushing of measuring system when
processing deliveries which have been transferred via
OBC.
0: No
1: Yes
2: Automatic
3.1.5.1.9
Force Delivery Stop
Cal.
1
0 (inactive)
Determines the time after which a delivery is
automatically terminated when no flow is recognized.
Function inactive
1-99 Time limit in minutes
3.1.5.1.0
Hide delivery
Cal.
1
0 (inactive)
When active, actual delivery quantity is not displayed
during delivery.
3.1.5.2
Parameter List 2
3.1.5.2.1
Access density
Calibr
ation
super
-visor
Drive
r
1
0
Defines parameter protection for product density
0: Seal
1: Supervisor
2: Driver