MultiFlow Address and contact details
Only for the English version of the program.
Parameter not active in German version.
Summary of all orders transmitted by the OBC on
one receipt
Volume division: Number of post-decimal places on
volume display.
Maximum number of discharges per receipt.
Minimum default volume for discharge
(in increments of 200 liters)
Minimum requirement from W&M for bill / delivery
receipt
Determines whether the retrospective modification of
prices is permitted with measured products.
Separator for decimal places: '.' or ','
IMPORTANT: Parameter not currently active. See
parameter 3.3.3.3.
Definition of product used to flush the measuring
system.
Specification of the quantity of product used to flush
the measuring system
Minimum pre-set quantity after a product change (due
to product contamination) in liters. Specify according
to calibration regulations.
Monitors flushing of measuring system when
processing deliveries which have been transferred via
OBC.
0: No
1: Yes
2: Automatic
Determines the time after which a delivery is
automatically terminated when no flow is recognized.
Function inactive
1-99 Time limit in minutes
When active, actual delivery quantity is not displayed
during delivery.
Calibr
ation
super
-visor
Drive
r
Defines parameter protection for product density
0: Seal
1: Supervisor
2: Driver