MN F09 002 US  DOK-383E  Issue/Rev. 3.65 (02/24)
MultiFlow  Address and contact details
Sening
®
is a registered trademark of FMC Technologies
305
Flow Control
No.
Name
Seal
K
Factory
Setting
Meaning
3.1.8.4
Flow Control
3.1.8.4.1
High Flow Rate ON
M
2
5.0 (liter)
Threshold for switchover from a reduced to a higher
flow rate:
Positive value: Amount in liters
Negative values: Flow rate in liters/min.
3.1.8.4.2
High Flow Rate OFF
M
2
20.0 (liter)
Remaining volume at which the switchover to reduced
flow rate takes place.
3.1.8.4.3
Wet Hose OFF
M
2
0.5 (liter)
Remaining volume at which the flow is stopped.
Used for all hoses, except for Dry Hose (G) or (P)
3.1.8.4.4
Dry Hose (G) OFF
M
2
0.5 (liter)
Remaining volume at which the flow is stopped.
Only applicable for Dry Hose and Gravity discharge.
3.1.8.4.5
Dry Hose (P) OFF
M
2
1.5 (liter)
Remaining volume at which the flow is stopped.
Only applicable for Dry Hose and pumped discharge.
3.1.8.4.6
Enable Adjustment
M
2
1 (yes)
Enables the automatic adjustment of
parameters 3.1.8.4.3 … 3.1.8.4.5
3.1.8.4.7
---
3.1.8.4.8
Start delay
M
3
0 m(sec.)
Delay time between hose selection and delivery start.
(0 .. 10s).
Draining
No.
Name
Seal
K
Factory
Setting
Meaning
3.1.8.5
Draining
3.1.8.5.1
Drain control
M
2
0 (no)
(up to version 5.00)
Activates a reminder concerning residue removal in
the event of product change.
3.1.8.5.2
Receipt draining
M
2
0 (no)
(up to version 5.00)
Parameter currently not in use. In a future program
version will activate printout of a receipt after residue
removal.
3.1.8.5.1
Residue removal
control
M
2
1
(version 5.00 and higher)
1 : Off
2: Stand-alone
Activates a reminder concerning residue removal in
the event of product change.
3: EPE2-manual
As described under 2; however, the wet leg sensor
connected to the EPE2 monitors the residue removal.
No restart of MultiFlow required after residue removal.
4: EPE2-AIII
As described under 3; however, the "Autom. residue
removal" menu item (menu 8) includes the option to
control a pump for the measuring system residue
removal via the EPE2 output.
5: EPE2-AI
As described under 4; but due to the system, instead
of a pump, a valve is connected to the EPE2 which
gives the additional option of a product change
between AI and AIII products.