MN F09 002 US DOK-383E Issue/Rev. 3.65 (02/24)
MultiFlow Address and contact details
Sening
®
is a registered trademark of FMC Technologies
Threshold for switchover from a reduced to a higher
flow rate:
Positive value: Amount in liters
Negative values: Flow rate in liters/min.
Remaining volume at which the switchover to reduced
flow rate takes place.
Remaining volume at which the flow is stopped.
Used for all hoses, except for Dry Hose (G) or (P)
Remaining volume at which the flow is stopped.
Only applicable for Dry Hose and Gravity discharge.
Remaining volume at which the flow is stopped.
Only applicable for Dry Hose and pumped discharge.
Enables the automatic adjustment of
parameters 3.1.8.4.3 … 3.1.8.4.5
Delay time between hose selection and delivery start.
(0 .. 10s).
(up to version 5.00)
Activates a reminder concerning residue removal in
the event of product change.
(up to version 5.00)
Parameter currently not in use. In a future program
version will activate printout of a receipt after residue
removal.
(version 5.00 and higher)
1 : Off
2: Stand-alone
Activates a reminder concerning residue removal in
the event of product change.
3: EPE2-manual
As described under 2; however, the wet leg sensor
connected to the EPE2 monitors the residue removal.
No restart of MultiFlow required after residue removal.
4: EPE2-AIII
As described under 3; however, the "Autom. residue
removal" menu item (menu 8) includes the option to
control a pump for the measuring system residue
removal via the EPE2 output.
5: EPE2-AI
As described under 4; but due to the system, instead
of a pump, a valve is connected to the EPE2 which
gives the additional option of a product change
between AI and AIII products.