MN F09 002 US  DOK-383E  Issue/Rev. 3.65 (02/24)
MultiFlow  Discharge
78
Sening® is a registered trademark of FMC Technologies
If a product change is being implemented between AI and AIII
products, it is essential that national regulations and operator
guidelines are observed.
After correct residue removal from the measurement system, a residual
quantity of residue is present in the measurement system (without
pipe). Details of this residual quantity are given in the relevant
measurement system documentation.
If an EPE2-AI is used, the input signal from the EPE2 must be inverted
via parameter 3.1.6.8.4.
After carrying out residue removal, continue with part 4 of the discharge
(see chapter 6.4 "Electronic hose selection (optional)" / page 78).
6.4 Electronic hose selection (optional)
The automatic hose selection is an option only included in software
version 2.0 or higher. This option is configured in parameter 3.1.8.1 (see
chapter 9.3.1.8.1 "Notes on the manual control of the hoses" / page
147).
In software versions lower than 3.10 the electronic hose selection will be
carried out before product selection.
For devices with manual hose selection you can skip this chapter.
Default: last selection
The automatic hose selection replaces manually operated pneumatic
switches. You are thereby able not only to select product and preset
volume but also the discharge pass directly at the MultiFlow.
Hos e Se le ct io n
Se le ct io n:
1 Un me te re d
2 We t Ho s e 1
3 (W et H os e 2)
4 Dr y Ho se
5 By pa ss 1
6 (B yp as s 2)
U p Do wn
- --