MN F09 002 US  DOK-383E  Issue/Rev. 3.65 (02/24)
MultiFlow  Address and contact details
306
Sening® is a registered trademark of FMC Technologies
No.
Name
Seal
K
Factory
Setting
Meaning
3.1.8.5.2
Residue removal
timeout
M
2
0 (no)
(version 5.00 and higher)
Timeout for the autom. draining of the measuring
system with the aid of the EPE2 in "EPE2 automatic"
mode. Residue removal stops automatically after this
period of time.
3.1.8.5.3
Residue removal
receipt
M
2
0 (no)
(version 5.00 and higher)
Parameter currently not in use. In a future program
version will activate printout of a receipt after residue
removal.
3.1.8.5.4
With product change
M
2
0 (no)
Residue removal query appears after each product
change, unless residue removal had previously been
detected.
3.1.8.6
---
No longer applicable from version 2.1 and higher;
see 3.1.8.4.3
3.1.8.7
Hose Set
Cal.
1
UVLB
Defines the hose paths that are used in the
measuring system for later selection.
B Bypass
D (L) Dry hose
G (S) Dry hose with Gravity discharge
P Pumped dry hose discharge
U Unmetered
W (V) Wet hose
Note: Each abbreviation may be used only
twice at the most.
Overfill prevention
No.
Name
Seal
K
Factory
Setting
Meaning
3.1.8.8
Overfill prevention
3.1.8.8.1
Overfill prevention
M
0
No
The control element function is transferred from the
overfill prevention to the MultiFlow.
No No monitoring, MultiFlow is not
an element of the delivery safety
system.
Frequency Input: A level sensor with frequency
output is used.
Switch Input: A level sensor with switch output
is used.
RF overfill prevention:
OP signal is transmitted via RF
and base station to the MultiFlow
3.1.8.8.2
Info
D
2
(0) no
Issue a message on change of status of a cable-
based overfill prevention.
3.1.8.9
Valve Compilation
M
2
0
Select Valve Compilation (see also 8.3.1.8.5))
0 General configuration
1 GVLx-xM, dry hose operation is modified
3.1.8.0
Blow Down
Cal.
1
8 (sec)
Applicable only for UK version:
Blow down of dry hose (duration)

Table of Contents