MN F09 002 US  DOK-383E  Issue/Rev. 3.65 (02/24)
MultiFlow  Address and contact details
304
Sening® is a registered trademark of FMC Technologies
No.
Name
Seal
K
Factory
Setting
Meaning
3.1.6.0.4.8.1.4
Inversion
M
2
0 (no)
Status of the allocated ext. output should assume
inverted status of the reference in/output.
3.1.6.0.4.8.1.5
Product dependency
M
2
0 (no)
Up to 5 project dependencies can be defined. (0, 10 ..
39)
3.1.6.0.4.8.2
Additional hose path
3.1.6.0.4.8.2.1
Use
M
2
0 (no)
Use output to control an additional hose path.
3.1.6.0.4.8.2.2
Designation
M
2
Designation of the additional hose path
CAN-Bus (lokal)
No.
Name
Seal
K
Factory
Setting
Meaning
3.1.7
Local CAN Bus
ATTENTION:
The settings for a local (internal) CAN Bus cannot
be altered until further notice.
3.1.7.1
Internal Node No.
M
2
0
Node number of the main board on the internal CAN
Bus.
3.1.7.2
Display No. 1
M
2
1
Node number of the first display on the internal CAN
Bus.
3.1.7.3
Display No. 2
M
2
0 (inactive)
Node number of the second display on the internal
CAN Bus.
Valve Control
No.
Name
Seal
K
Factory
Setting
Meaning
3.1.8
Valve control
3.1.8.1
Path Selection
Cal.
Basic control
Defines the structure of the measuring system used:
1. Basic control: Basic version with manual
operation of a control block and product release.
2. High/Low Flow: as above, but with reduction of
the flow at the start and end of the discharge.
3. Fully electronic: Control switch replaced by
electronical valve controller.
(not supported in current version)
4. Expanded electronical control: as described in 3.,
but combined with flow control (however, no
additive dosing possible).
5. With blow down (GB):
special control for GB, with flow control, additive
pump, blow down of the dry hose after the
discharge and product transfer / self loading.
6. Expanded electronical control: as described in 3.,
with flow control & additive dosing (no unmetered
discharge)
3.1.8.2
Turn-on Delay
M
2
3 (sec)
Delay on activating the control valve before the
release valve.
3.1.8.3
Turn-off Delay
M
2
3 (sec)
Delay on closing the release valve before the control
valve.