MultiFlow  Address and contact details
3.1.4.5.7.1
Copy query
M
3
0 (no)
Activates request for an additional copy of the receipt
immediately after printing the original.
3.1.4.5.7.2
Number of Copies
M
3
0
Standard-setting for the number of copies to be
printed after the printing of the original parameters in
conjunction with 3.1.4.5.7.1.
0 After each print of a copy, the query shows
up again.
1..10 After printing of the original, the number of
copies to be printed afterwards can be set
(only once).
3.1.4.5.8
Office transfer
3.1.4.5.8.1
End data transfer
M
3
1 (yes)
After completion of the delivery, activates the status
screen which is displayed during the external data
transfer from the EMIS to the office interface (e.g.
FTP server).
3.1.4.5.8.2
OBC connection
M
3
2 (yes)
Activates wait screen during synchronization of
MultiFlow and EMIS before start of delivery.
1 inactive
2 always
3 before delivery
4 after delivery
3.1.4.5.9
Compartment
number
M
3
0 (no)
Activates request for the compartment number in the
delivery pre-set.
3.1.4.5.0
Order number
3.1.4.5.0.1
Order number
M
3
0 (no)
Activates request for order number in the delivery
pre-set.
3.1.4.5.0.2
Standard pre-set
D/M
3
Standard text for order number
3.1.4.5.0.3
Enhanced protection
parameter
M
3
0 (no)
Modification of the parameter 3.1.4.5.0.2. Only after
entering the master password.
3.1.4.6
No-load
Measurement
(version 5.02 and higher)
3.1.4.6.1
Activate
Measurement
M
3
0 (nein)
Activation of the no-load measurement
3.1.4.6.2
Minimum amount
M
3
10
Minimum amount of product which needs to be
measured in the amount of time specified in 3.1.4.6.3
so that the delivery is found valid and continued.
(1…50 L)
3.1.4.6.3
Active Period
M
3
30
Period in which the minimum quantity of product
(3.1.4.6.2) must be measured during idling, so that
the measurement is found valid and continued.
(1...300 s)
3.1.4.6.4
Timeout
M
3
60
Period after which the product flow is terminated
automatically without any further active idle
measurement. (1 .180 s)
3.1.4.6.5
Info
M
3
0 (no)
Status output in the History window. Helpful during
the configuration phase of the no-load measurement.
3.1.4.7
---
3.1.4.8
Add Surcharge
M
3
0 (no)
Activates special surcharge on the receipt.
3.1.4.9
Default Surcharge
M
3
31
Product code for special surcharge (e.g. transport
duty). Default can be changed by the user on site.
3.1.4.0
Billing
3.1.4.0.1
Billing
M
3
1 (gross)
Activates/deactivates the billing option
(c.f. also 3.1.4.5.4):
0: no bill
1: bill based on gross prices
(with VAT incl.)
2: bill based on net prices
(without VAT)
3.1.4.0.2
Second tax rate
M
3
Only for the English version of the program.
Parameter not active in German version.