The status report is divided into different sections. The upper section
contains the specific device data for the MultiFlow and the time the report
was created.
The central section gives clear information about the current monitor
status and the status of the connection to the external sensor interface
(SI). If the monitor has been deactivated (status "INACTIVE") additional
information is given as to how the deactivation was triggered. This can be
caused by the change in status of a sensor with activated alarm message
(“-Sensor-”) or manually by the user (“-Manual-”, menu 4.8.1).
The bottom section of the status report contains additional information
about the sensor monitor. Along with the time and the unique monitoring
ID, the GPS position at the time the sensor monitor was activated is also
given. A “-C-” indicates that GPS data was available at the time of the
activation, while an “-L-” indicates that no GPS data was received at the
time and this is the most recent valid GPS position.
Example of a conversion of the coordinates into a format supported by
Google Maps:
N.5338.54642 , E.953.37069 -> +53°38.54642, +09°53.37069
-----------------------------------------
Status
INACTIVE
- Sensor -
SI Connected
-----------------------------------------
Date : 12.12.2011 11:03
ID : 000001
GPS -C- : N 05338.54642
E 00953.37156
-----------------------------------------