Both volumes Vt and V15 are printed
depending on product parameter
3.5.nn.7.1 chapter 9.10 "Product
Registers (35nn..)" / page 166..
In addition to these five elements there are other modules, e.g. date,
time, driver name, etc. All available form elements are listed in section
"Description of Text Modules" / p. 202 .
Parameter 3.1.5.1.4 (minimum layout) is subject to calibration protection,
i.e. with a sealed unit no modifications can be undertaken.
The editor for configuration of the receipt layout is subject to master
protection, i.e. even with a sealed unit modifications can be undertaken,
taking into account the minimum layout.
The minimum layout represents only a minimum requirement. In the
receipt it is of course possible for additional elements to be printed at
any time.
In order to ensure that the receipt layout corresponds to the current
regulations (e.g. PTB-A5, chapter 5.1.3), the following procedure is
required:
•
Set parameter 3.1.5.1.4 (minimum layout) to the new value '2,3,11,25'.
•
Exit the menu completely by pressing the <STOP> key a number of
times. If the actual receipt layout does not correspond to the minimum
layout, an indication is received of a parameter error. In this event the
corresponding form element is to be corrected in the layout editor.