260
Sening® is a registered trademark of FMC Technologies
MN F09 002 US  DOK-383E  Issue/Rev. 3.65 (02/24)
MultiFlow  Miscellaneous Information
Settings to the MultiFlow:
Menu option
Value to be entered
Meaning
3.2.1
Printer selection
7
TM-U295
3.2.6.1
LDT protocol
0
OFF
3.2.4
Parity check
1
Even parity
14.6.2
MultiFlow versions from V3.49
For MultiFlow versions with a separate option to set the number of data
bits set the data format to 8E1 as follows. This allows the use of special
characters even in secure data transfer.
The printer is factory-set for connection to the Multi-Flow.
No further adjustments need to be made to the printer.
The following factory settings are to be checked on the printer in the
event of a fault. The switches to set the operating mode of the TM-U295
are located on the bottom of the unit.
The following factory settings are to be checked at the printer:
Make the following settings to the MultiFlow before setting the electronic
seal in order to operate the TM-U295 correctly (without FDW converter).
These are available from the SW Version 3:49 [3:49] DE and allow the
use of special characters, even with secure data transmission.
DSW1
Position
Function
1
OFF
Transfer error:
“?“ print
2
OFF
512 byte data buffer
3
ON
Handshake XON/XOFF
4
OFF
8 bits
5
ON
Parity used
6
ON
Even parity
7
OFF
9600 baud
8
OFF
9
OFF
No pin 6: Reset signal
10
OFF
No pin 25: Reset signal