EasyManuals Logo

Telit Wireless Solutions ML865G1 Reference Guide

Telit Wireless Solutions ML865G1
1039 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #1018 background imageLoading...
Page #1018 background image
ME310G1/ME910G1/ML865G1 AT Commands Reference Guide
80617ST10991A Rev. 11 Page 1018 of 1039 2021-09-23
Not Subject to NDA
How to manage timer values octet.
T3412ext value:
Bits 5 to 1 represent the binary coded timer value.
Bits 6 to 8 defines the timer value unit as follows:
Bits
8 7 6
0 0 0 value is incremented in multiples of 10 minutes
0 0 1 value is incremented in multiples of 1 hour
0 1 0 value is incremented in multiples of 10 hours
0 1 1 value is incremented in multiples of 2 seconds
1 0 0 value is incremented in multiples of 30 seconds
1 0 1 value is incremented in multiples of 1 minute
1 1 0 value is incremented in multiples of 320 hours
1 1 1 value indicates that the timer is deactivated.
Example: 10101100 -> 101 means values is incremented in multiples of 1
minute, 01100 means 12 -> the obtained value is 12 minutes
T3324 value:
Bits 5 to 1 represent the binary coded timer value.
Bits 6 to 8 defines the timer value unit for the GPRS timer as follows:
Bits
8 7 6
0 0 0 value is incremented in multiples of 2 seconds
0 0 1 value is incremented in multiples of 1 minute
0 1 0 value is incremented in multiples of decihours
1 1 1 value indicates that the timer is deactivated.

Table of Contents

Other manuals for Telit Wireless Solutions ML865G1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Telit Wireless Solutions ML865G1 and is the answer not in the manual?

Telit Wireless Solutions ML865G1 Specifications

General IconGeneral
BrandTelit Wireless Solutions
ModelML865G1
CategoryWireless modules
LanguageEnglish

Related product manuals