ME310G1/ME910G1/ML865G1 AT Commands Reference Guide
80617ST10991A Rev. 11 Page 479 of 1039 2021-09-23
Not Subject to NDA
<type>=4
The module wakes up in "alarm mode" if at the alarm time it was
off, otherwise it remains fully operative. In both cases the module
brings the alarm pin high, provided that one has been set (using
#ALARMPIN or #GPIO) and keeps it in this state until a #WAKE or
#SHDN command is received or a 90 seconds timer expires. If the
device is in "alarm mode" and it does not receive the #WAKE
command within 90s then it shuts down.
<type>=5
The module will make both the actions as for <type>=2 and
<type>=3.
<type>=6
The module will make both the actions as for <type>=2 and <type>=4.
<type>=7
The module will make both the actions as for <type>=3 and <type>=4.
<type>=8
The module wakes up in "alarm mode" if at the alarm time it was off,
otherwise it remains fully operative. In both cases the module sets
high the RI output pin. The RI output pin remains high until next
#WAKE issue or until a 90s timer expires. If the device is in "alarm
mode" and it does not receive the #WAKE command within 90s. After
that it shuts down.

Table of Contents

Other manuals for Telit Wireless Solutions ML865G1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Telit Wireless Solutions ML865G1 and is the answer not in the manual?

Telit Wireless Solutions ML865G1 Specifications

General IconGeneral
BrandTelit Wireless Solutions
ModelML865G1
CategoryWireless modules
LanguageEnglish

Related product manuals