ME310G1/ME910G1/ML865G1 AT Commands Reference Guide
80617ST10991A Rev. 11 Page 480 of 1039 2021-09-23
The "alarm mode" is indicated by hardware pin CTS to the ON
status and DSR to the OFF status, while the "power saving" status
is indicated by a CTS - OFF, DSR - OFF and USB_VBUS - OFF
status. The normal operating status is indicated by DSR - ON or
USB_VBUS - ON status.
During the "alarm mode" the device will not make any network
scan and will not register to any network and therefore is not able
to dial or receive any call or SMS.
The only commands that can be issued to the module in this state
are the #WAKE and #SHDN, every other command must not be
issued during this state.
AT+CALA?
Read command returns the list of current active alarm settings in the
device, in the following format:
[+CALA: <time>,<n>,<type>,[<text>],<recurr>,<silent>]
Note: on READ command <time> does not include the time zone.
AT+CALA=?
Test command returns the list of supported index values, alarm types,
maximum length of the text to be displayed in the URC +CALA, maximum
length of <recurr> and supported <silent>s, in the format:
+CALA: (list of supported <n>s),(list of supported
<type>s),<tlength>,<rlength>,(list of supported <silent>s)
Additional info: