ELECTRICAL
4181383 First Edition 4-23
4
With the starter solenoid energized, voltage is also
provided from the starter solenoid contacts to control
module fuel pull-in input terminal, activating the input.
With the fuel pull-in input activated, control module fuel
pull-in output terminal J3-12 provides voltage to the fuel
shutoff solenoid pull-in coil, energizing the coil. With the
pull-in coil energized, the solenoid plunger retracts.
When the solenoid plunger is fully retracted, an internal
switch opens the pull-in coil circuit. This prevents
extended activation of the high current pull-in coil. The
hold-in coil keeps the solenoid plunger in the retracted
position until it is de-energized.
With the solenoid plunger retracted, fuel is allowed to flow
and as the starter motor cranks the engine, the engine
starts operating.