Device Software Update
Step 1: Creating Project Package
This step shows if the Project Package was created successfully.
Step 2: Connecting device
This step shows if the USB device is connected successfully.
Step3: Transferring project
This step shows the progress of the project transfer to the USB drive.
If the transfer fails an error code and error text is shown under the progress bar.
Otherwise a message (6) is shown that the project was succsessfully transferred to
the USB drive.
If the project package was successfully transferred to the USB drive, a new
directory "updater" has been created. It contains 2 files, a file called
"mmscript.xml" and the project package file, here called "MyProject.ud4".
Once the Project Package was transferred to the USB drive successfuly, the
USB drive has to be plugged into the USB port of the device to update the project
on the device.
The project will only be installed on the device if the variable @enableUpdater
is set to 0x1 or 0x3. The default value is 0x1.
The next time you open the Updater for the same project, the last used path or
USB drive will be set again.
The path or USB drive is saved in HostSettings.ini file.
The USB drive is not unmounted when the project is transferred to the USB
drive.
Error Codes during Transfer
If the USB Transfer has not finished properly, an Error Code with Error Message
is shown on the USB Transfer Page. This shall help to identify the issue quickly.