How To
After another time, set with @PWR_TimeToPowerOff (again between 0 and 2332800
seconds), the device turns Off.
Here is a rough overview how much power the devices draw in which mode.
4.7" iMX.35
7" iMX.25
7" iMX.6
12" iMX.6
On
430
900
1000
1600
Low Power
160
200
200
300
Sleep
Off
< 3
< 3
< 3
< 3
Only in Sleep or Off mode it's safe to remove clamp 30 (power plus). Disconnecting clamp 30
in On or Low Power is not good and can damage data.
When returning to On mode, the starting time is highly reduced when starting from Low