ERROR CODE and TROUBLESHOOTING
8 - 327
Cause/Section Step Check item Measures
Developer unit 1 Is the layer of the developer material
on the developer sleeve where the
density is uneven thin or lacking?
Remove the foreign matter in the
developer unit.See “2. Removal of
foreign matter in the developer
unit” in “7.6.7 Developer unit (K, Y,
M and C)”.
Clean the developer unit.See “1.
Cleaning” in “7.6.7 Developer unit
(K, Y, M and C)”.
2 Does uneven image density occur
again?
Adjust the doctor-sleeve gap close to
the upper limit value of the
adjustment standard.See “6.4.3
Adjustment of the doctor-sleeve gap”.