e-STUDIO5540C/6540C/6550C/5560C/6560C/6570C © 2011 - 2015 TOSHIBA TEC CORPORATION All rights reserved
DISASSEMBLY and REPLACEMENT
4 - 106
4.6.19 Needle electrode cleaner detection sensor-K/C/M/Y (S30/S31/S32/
S33)
4.6.20 Needle electrode cleaner motor-K/-C/-M/-Y (M23/M24/M25/M26)
(1) Take off the drum cleaner unit.
P. 4-95"4.6.2 Drum cleaner unit"
(2) Disconnect 1 connector and release 3
latches and then take off the needle
electrode cleaner detection sensor.
Fig. 4-308
(1) Take off the process unit.
P. 4-110"4.6.24 Developer unit"
(2) Release 2 hooks. Then lift up the motor
holder.
(3) Disconnect 1 connector and then take off the
motor holder.
Fig. 4-309
(4) Release 2 hooks and then take off the duct.
Fig. 4-310
(Y)
(K)
(C)
(M)
Needle electrode cleaner detection sensor