EasyManua.ls Logo

Toshiba E-Studio 5540c - State Transition Diagram of Self-Diagnosis Modes; About each Mode

Toshiba E-Studio 5540c
1499 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
e-STUDIO5540C/6540C/6550C/5560C/6560C/6570C © 2011 - 2015 TOSHIBA TEC CORPORATION All rights reserved
SELF-DIAGNOSTIC MODE
5 - 2
Notes:
The following modes cannot be carried out since they are provided only for production.
[2]+[CLEAR]+[POWER]
[7]+[CLEAR]+[POWER]
[8]+[CLEAR]+[POWER]
The menu below can be carried out in the following mode; however, there is no effect on the
equipment even if it is done.
[9]+[CLEAR]+[POWER]
0. Turn Line Mode ON
1. Turn Line Mode OFF
3. Restore Machine Information
[D] State transition diagram of self-diagnosis modes
Fig.5-1
*1 If you have used a self-diagnostic mode, turn the power OFF before the customer starts using the
equipment
*2 Mode shown in the table “[C] List of modes”
[E] About each mode
Control panel check mode (01)
Operation procedure
Notes:
A mode can be cancelled by [POWER] OFF/ON when the LED is lit and the LCD is blinking.
Button Check
Buttons with LED: Press to turn OFF the LED.
Buttons without LED: Press to display the message on the control panel.
Authentication
screen
Normal
Warming up
Ready
[POWER]
OFF
To user
Each mode
Self-diagnosis
mode
*1
*2
[POWER]
ON
[0][1]
[POWER]
LED lit/
LCD blinking
[START]
[START]
(Button check)
[POWER] OFF/ON
(Exit)

Table of Contents