7
© 2011 - 2015 TOSHIBA TEC CORPORATION All rights reserved e-STUDIO5540C/6540C/6550C/5560C/6560C/6570C
PREVENTIVE MAINTENANCE (PM)
7 - 3
7.2.4 Counter Clearing
The counter indicating “current number of prints and driving time” used for the PM display function is
reset by entering “0” in it or clearing it in the PM support mode.
Notes:
Even if “0” is entered in the PM management setting value of the setting mode (08), the
corresponding counter for the PM display is not reset. Be sure to clear the counter in the PM
support mode when the maintenance is finished.
The reset condition of each counter is as follows:
08-6194: Current value of PM counter [process unit (K)]
08-6195: Current value of PM time counter [process unit (K)]
When the current value of “CLEANER/DRUM/CHARGER (K)” on the main screen or “DRUM (K)” on
the sub-screen in the PM support mode is cleared, the counter is reset.
08-6196: Current value of PM time counter [process unit (Y)]
08-6197: Current value of PM time counter [process unit (Y)]
When the current value of “CLEANER/DRUM/CHARGER (Y)” on the main screen or “DRUM (Y)” on
the sub-screen in the PM support mode is cleared, the counter is reset.
08-5564: Current value of PM counter [process unit (M)]
08-5565: Current value of PM time counter [process unit (M)]
When the current value of “CLEANER/DRUM/CHARGER (M)” on the main screen or “DRUM (M)”
on the sub-screen in the PM support mode is cleared, the counter is reset.
08-5566: Current value of PM counter [process unit (C)]
08-5567: Current value of PM time counter [process unit (C)]
When the current value of “CLEANER/DRUM/CHARGER (C)” on the main screen or “DRUM (C)” on
the sub-screen in the PM support mode is cleared, the counter is reset.
08-5576: Current value of PM counter [parts other than the PM parts of the process unit]
08-5577: Current value of PM time counter [parts other than the PM parts of the process unit]
When the current value of “2nd TRANSFER” on the main screen or “2nd TRANSFER ROLLER” on
the sub screen in the PM support mode is cleared, the counter is reset.