EasyManua.ls Logo

Toshiba E-Studio 5540c - Judgment Threshold Adjustment for Blank Original; Background Offsetting Adjustment for RADF

Toshiba E-Studio 5540c
1499 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6
© 2011 - 2015 TOSHIBA TEC CORPORATION All rights reserved e-STUDIO5540C/6540C/6550C/5560C/6560C/6570C
SETTING ADJUSTMENT
6 - 45
6.2.17 Judgment threshold adjustment for blank original
The judgment level is adjusted for automatic identification of whether the original set is blank or not.
This adjustment is made when “Omit Blank Page” is selected on the control panel.
The adjustment value is simultaneously applied to all modes at PPC and scanning.
<Adjustment Mode (05)>
<Procedure>
The procedure is the same as that of P. 6-33"6.2.2 Density adjustment".
6.2.18 Background offsetting adjustment for RADF
The background level for scanning originals with the RADF is adjusted when the background fogging at
the scanning of the manually-set original and the original used with the RADF is different. This is to
adjust the level of the background image removed when the scanning of the originals with the RADF is
performed.
<Adjustment Mode (05)>
<Procedure>
The procedure is the same as that of P. 6-33"6.2.2 Density adjustment".
Code Item to be adjusted Remarks
7618 Judgment threshold
adjustment for blank
original
The larger the value is, the more an original tends to be
judged as a bank sheet.
Acceptable values: 0 to 255 (Default: 128)
Color mode Code Remarks
Full Color 7764 The larger the value is, the lighter the background density
becomes.
Acceptable values: 0 to 255
(Default: 128)
Mono Color 7765
Twin Color
mode
7766
Black 7025