6
© 2011 - 2015 TOSHIBA TEC CORPORATION All rights reserved e-STUDIO5540C/6540C/6550C/5560C/6560C/6570C
SETTING ADJUSTMENT
6 - 125
6.12.7 RADF opening/closing switch adjustment
Adjust the bracket position so that the sensor is turned ON when the height “J” becomes 145 mm or
less (within the empty weight falling limit).
Fig.6-117
(1) Take off the RADF rear cover.
P. 4-258"4.11.3 RADF rear cover"
(2) Loosen the fixing screw of the bracket. Slide
the bracket vertically using the scale as a
guide to adjust the position where the switch
is turned ON.
(3) Tighten the fixing screw of the bracket. Install
the RADF rear cover.
Fig.6-118