4
© 2011 - 2015 TOSHIBA TEC CORPORATION All rights reserved e-STUDIO5540C/6540C/6550C/5560C/6560C/6570C
DISASSEMBLY and REPLACEMENT
4 - 223
4.10.19 Bridge unit transport roller-3
(5) Take off the bridge unit transport roller-2 by
removing 2 E-rings and a bearing.
Fig. 4-647
(1) Take off the reverse roller.
P. 4-225"4.10.20 Reverse roller"
(2) Take off transport guide-2.
P. 4-229"4.10.25 Bridge unit path
entrance sensor (S55)"
(3) Take off bridge unit exit roller-1.
P. 4-225"4.10.21 Bridge unit exit roller-1"
(4) Take off the transport guide unit by removing
2 screws and disconnecting the connector.
Fig. 4-648
(5) Remove the spring and 2 screws. Then
remove the actuator.
Fig. 4-649
Bridge unit transport roller-2
Bearing
Bearing