6
© 2011 - 2015 TOSHIBA TEC CORPORATION All rights reserved e-STUDIO5540C/6540C/6550C/5560C/6560C/6570C
SETTING ADJUSTMENT
6 - 117
6.12.2 RADF height adjustment
Notes:
Check if the image adjustment for the equipment is performed properly before this adjustment of
the RADF.
[A] Adjustment
(1) Remove the top left cover.
P. 4-3"4.1.6 Top left cover"
(2) Close the RADF.
(3) Light the exposure lamp.
Turn the power ON while pressing [0] and
[3] simultaneously.
Key in [267] and then press the [START]
button. The exposure lamp is turned ON
for a given length of time.
(4) Visually check the gap between platen guide
holder “A” and upper surface of the original
glass “B” from the left hand side of the
equipment. If the value is not within the
tolerance, perform the adjustment according
to the following procedure.
[Tolerance of the gap]
Rear side: 0 - 0.2 mm
Front side: 0 mm
Fig.6-99
(5) Close the RADF. Adjust it by turning the
adjustment screws on the hinges.
Adjust the gap on the rear side by means
of the screw on the hinge on the feed side
(right side) of the RADF.
Turn it clockwise ................ Heightened
Turn it counterclockwise .... Lowered
Fig.6-100
Adjust the gap on the front side by means
of the screw on the hinge on the exit side
(left side) of the RADF.
Turn it clockwise ................ Lowered
Turn it counterclockwise .... Heightened
Fig.6-101
0~0.2mm
0mm
B
A
B
A