DISASSEMBLY and REPLACEMENT
4 - 250
4.10.48 Fuser transport sensor (S65)
(4) Remove the duplexing unit path exit sensor
from the sensor bracket.
Fig. 4-728
(1) Pull out the duplexing unit.
(2) Remove 3 screws and take off transport
guide.
Fig. 4-729
(3) Remove 1 screw and take off the sensor
bracket.
(4) Disconnect the connector from the fuser
transport sensor.
Fig. 4-730
Duplexing unit path exit sensor
Shoulder screw