FIRMWARE UPDATING
11 - 19
Notes:
This step is unnecessary for a patch update.
[B] Confirmation of the updated data
After the updating is completed, check each data version in the Setting Mode (08) to confirm that the
data were overwritten properly.
P. 11-51"11.5 Confirmation of the updated data"
[C] Adjustment
Perform the adjustment of the equipment.
• Performing Image Quality Control (05-2742):
P. 6-4"6.1.3 Performing Image Quality Control"
• Adjustment of Color Registration Control (05-4719):
P. 6-7"6.1.4 Adjustment of Color Registration Control"
• Automatic gamma adjustment <PPC> (05-7869) (using [4][FAX] test pattern):
P. 6-31"6.2.1 Automatic gamma adjustment"
• Automatic gamma adjustment < PRT > (05-8008) (using [70][FAX] test pattern):
P. 6-49"6.3.1 Automatic gamma adjustment"
[D] Display during the update
Update is performed in parallel as shown in the transition diagram below.
Item Selection Screen for Update
Update Completed
[
System ROM
][
Engine ROM
] [PFC ROM]
[
Scanner ROM
] [
Master data
] [RADF ROM]
2. ENGINE
FIRMWARE
1. SYSTEM
FIRMWARE(OS Data)
3.SCANNER
FIRMWARE
4. SYSTEM
SOFTWARE(HD Data)
5. RADF FIRMWARE 6. PFC FIRMWARE