4
© 2011 - 2015 TOSHIBA TEC CORPORATION All rights reserved e-STUDIO5540C/6540C/6550C/5560C/6560C/6570C
DISASSEMBLY and REPLACEMENT
4 - 173
4.9.2 Pressure roller cover
Notes:
Follow the procedure below for the
installation.
1. Insert the fuser unit into the equipment by
setting the plates on both sides of the unit
onto the guide of the equipment.
2. Fix the fuser unit with 2 screws by
pushing it to the equipment. Tighten the
screws securely until they no longer turn.
3. Fix the handle grips with 1 screw.
4. Turn the handle grips to engage the gear
of the equipment with that of the fuser
unit.
Fig. 4-496
(1) Take off the fuser unit.
P. 4-172"4.9.1 Fuser unit"
(2) Remove 4 screws and then take off the
pressure roller cover [1].
Fig. 4-497
Notes:
When installing, pay attention to the following
points.
Be sure that the harnesses do not come
out from the entrance guide cover.
Be sure that the pressure roller cover is
positioned under the entrance guide
cover.
Fig. 4-498
[
1
]