Code Function Speed Code Function
Procedur
Drum motor-K ON
(Operation available without
the process unit)
611
Drum motor-YMC
ON(Operation available without
the process unit)
Decelerat
ed by 1/2
661 Code No.611 function OFF
1
(*1)
612
Developer unit motor-K
ON(Operation available without
the process unit)
Decelerat
ed by 1/2
662 Code No.612 function OFF 1
613
Developer unit motor-YMC
ON(Operation available without
the process unit)
Decelerat
ed by 1/2
663 Code No.613 function OFF 1
616
Transfer belt motor
ON(Operation available without
the process unit)
Decelerat
ed by 1/2
666 Code No.616 function OFF
1
(*2)
620
Feed motor (normal rotation)
ON(Paper fed from 1st drawer)
Decelerat
ed by 1/2
670 Code No.620 function OFF 1
621
Feed motor (reverse rotation)
ON(Paper fed from 2nd
drawer)
Decelerat
ed by 1/2
671 Code No.621 function OFF 1
622 Feed/transport motor ON
Decelerat
ed by 1/2
672 Code No.622 function OFF 1
623 Tandem LCF feed motor ON
Decelerat
ed by 1/2
673 Code No.623 function OFF 1
624 Transport motor-1 ON
Decelerat
ed by 1/2
674 Code No.624 function OFF 1
625 Transport motor-2 ON
Decelerat
ed by 1/2
675 Code No.625 function OFF 1
626 Bypass motor ON
Decelerat
ed by 1/2
676 Code No.626 function OFF 1
627
Option LCF transport motor
ON
Decelerat
ed by 1/2
677 Code No.627 function OFF 1
628 Registration motor ON
Decelerat
ed by 1/2
678 Code No.628 function OFF 1
629
Fuser motor (normal rotation)
ON
Decelerat
ed by 1/2
679 Code No.629 function OFF 1
630
Bridge unit transport entrance
motor ON
Decelerat
ed by 1/2
680 Code No.630 function OFF 1
632
Reverse motor (normal
rotation) ON
Decelerat
ed by 1/2
682 Code No.632 function OFF 1
634
Reverse motor (reverse
rotation) ON
Decelerat
ed by 1/2
684 Code No.634 function OFF 1
636
Bridge unit transport exit motor
(normal rotation) ON (lower
exit tray direction)
Decelerat
ed by 1/2
686 Code No.636 function OFF 1
638
Bridge unit transport exit motor
(reverse rotation) ON (upper
exit tray direction)
Decelerat
ed by 1/2
688 Code No.638 function OFF 1
640
Exit motor (normal rotation)
ON (lower exit tray direction)
Decelerat
ed by 1/2
690 Code No.640 function OFF 1
642
Exit motor (reverse rotation)
ON (upper exit tray direction)
Decelerat
ed by 1/2
692 Code No.642 function OFF 1
644 ADU motor-2 ON
Decelerat
ed by 1/2
694 Code No.644 function OFF 1
646 ADU motor-1 ON
Decelerat
ed by 1/2
696 Code No.646 function OFF 1
*1
Fully pull out the EPU tray toward you while the transfer belt remains. If it is not fully pulled out,
1
(*1)
Decelerat
ed by 1/2
610 660 Code No.610 function OFF