e-STUDIO5540C/6540C/6550C/5560C/6560C/6570C © 2011 - 2015 TOSHIBA TEC CORPORATION All rights reserved
ERROR CODE and TROUBLESHOOTING
8 - 182
[CD81] Waste toner transport motor locking error
[CD82] TRU waste toner full-status error
Check item Measures
TRU waste toner motor (M10) • Motor check
(Perform the output check: 03-239)
• Connector check
• Harness check
• Drive section check
ADU board • Connector check (CN491, CN497)
• Board check
PFU board • Connector check (CN511)
• Board check
Replace parts Remarks
TRU waste toner motor
ADU board
PFC board
Classification Error item
Process related service call The auger (waste toner box side) in the TRU waste toner
transport path does not rotate.
Check item Measures
TRU waste toner transport motor
(M11)
• Motor check
(Perform the output check: 03-240)
• Connector check
• Harness check
• Drive section check
ADU board • Connector check (CN491, CN497)
• Board check
PFC board • Connector check (CN511)
• Board check
Replace parts Remarks
TRU waste toner transport motor
ADU board
PFC board
Classification Error item
Process related service call
Check item Measures
TRU waste toner box • Check if the TRU waste toner box is full of used toner.
Replace it, if it is full.