8.3 RFID channels — process output data
Process output data — HF compact and UHF compact operating modes
Byte no. Bit
PROFINET Modbus
EtherNet/
IP
7 6 5 4 3 2 1 0
Channel 0
n + 0 0 Command code (CMDC)
n + 1 1
n + 2 2 Loop counter for rapid processing (RCNT)
n + 3 3 Memory area (DOM) — only available with UHF applications
n + 4 4 Start address (ADDR)
n + 5 5
n + 6 6
n + 7 7
n + 8 8 Length (LEN)
n + 9 9
n + 10 10 Length of UID/EPC (SOUID)
n + 11 11 Reserved
n + 12 24 Write data Byte 0
n + 13 25 Write data Byte 1
n + 14 26 Write data Byte 2
n + 15 27 Write data Byte 3
n + 16 28 Write data Byte 4
n + 17 29 Write data Byte 5
n + 18 30 Write data Byte 6
n + 19 31 Write data Byte 7
… … …
n + 139 151 Write data Byte 127
Channel 1
n + 140…
279
152…303 Assignment identical to channel 0