8.8.16 Direct read/write head command
NOTE
The command code for rapid processing with the loop counter is 0x2060 (hex.) or
8288 (dec.).
A direct command can be used to send commands directly to the read/write device from the
read/write head protocol. The commands are defined and interpreted via specifications in the
read and write data.
NOTE
The read/write head protocol is not part of this documentation and has to be re-
quested from and released specially by Turck. Questions on the read/write head pro-
tocol should be addressed to Turck.
See description of the output data, p. [}105].
Request
Loop counter See description of the output data
Command code 0x0060 (hex.), 96 (dec.)
Read/write head address See description of the output data
Length UID/EPC 0
Start address Not required
Length Length of the description of the direct command in the
write data, specification in bytes
Timeout See description of the output data
Write fragment No. 0
Read fragment No. See description of the output data
Write data Description of the direct command
See description of the input data, p. [}100].
Response
Loop counter See description of the input data
Response code 0x0060 (hex.), 96 (dec.)
Length Length of the description of the direct command in the
write data
Error code See description of the input data
Tag in
detection range
See description of the input data
Data (bytes) available See description of the input data
Tag counter See description of the input data
Write fragment No. 0
Read fragment No. See description of the input data
Read data Response to the direct command