9.5 Using HF bus mode
9.5.1 Executing a command in HF bus mode
Set parameter data:
Select HF bus mode.
Activate connected read/write heads.
Set the output data:
Set the start address for the command.
Set the required read/write head address.
Enter the command code.
Send the command to the read/write head.
9.5.2 Replacing bus-capable read/write heads
Remove the faulty read/write head.
Connect a new read/write head with the default address 68 or 0 (factory setting …/C53).
If multiple read/write heads are being replaced: Connect the read/write heads in the
order of the connection, i.e. connect the read/write head with the lowest address first.
a Addresses are allocated in ascending order to the read/write heads in the order in which
the heads were connected. The lowest address is automatically assigned to the next
read/write head with the default address 68 that is connected.
a If the LED on the read/write head is permanently lit, this indicates that the addressing is
complete.