8.8.25 Command: Lock DSFID in HF tag
The Lock DSFID in HF tag command locks the DSFID byte on an HF tag.
NOTE
The command is supported by HF read/write heads revision xV99 or later.
NOTE
It is not possible to lock a DSFID byte that has already been locked.
The fault signal 0xF102 will appear
(air interface error: timeout).
See description of the output data, p. [}105].
Request
Loop counter See description of the output data
Command code 0x0096 (hex.), 150 (dec.)
Read/write head address See description of the output data
Length UID/EPC Not required
Start address Not required
Length Not required
Timeout See description of the output data
Write fragment No. 0
Read fragment No. See description of the output data
Write data Not required
See description of the input data, p. [}100].
Response
Loop counter See description of the input data
Response code 0x0096 (hex.), 150 (dec.)
Length Not required
Error code See description of the input data
Tag in
detection range
See description of the input data
Data (bytes) available See description of the input data
Tag counter See description of the input data
Write fragment No. 0
Read fragment No. See description of the input data
Read data Not required