Setting
RFID channels — overview of commands
Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com
07.00 | 2022/09 | 153
8.8.27 Command: Reset read/write head password
NOTE
The command is only available for applications with UHF tags and the HF tags with
chip types EM42… and NXP SLIX2.
The Reset read/write head password command directly resets the password for a write access,
read access or kill command in the read/write device. The password function is switched off,
there is no password exchange between the read/write device and the password.
In HF applications, the password function is available in single-tag mode only. A fault signal is
output with multitag applications. To troubleshoot, set the HF: multitag parameter to 0: multi-
tag mode off.
See description of the output data, p. [}105].
Request
Loop counter See description of the output data
Command code 0x0101 (hex.), 257 (dec.)
Read/write head address See description of the output data
Length UID/EPC Not required
Start address Not required
Length Not required
Timeout See description of the output data
Write fragment No. 0
Read fragment No. See description of the output data
Write data Not required
See description of the input data, p. [}100].
Response
Loop counter See description of the input data
Response code 0x0101 (hex.), 257 (dec.)
Length Not required
Error code See description of the input data
Tag in
detection range
See description of the input data
Data (bytes) available See description of the input data
Tag counter See description of the input data
Write fragment No. 0
Read fragment No. See description of the input data
Read data Not required