Setting
RFID channels — overview of commands
Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com
07.00 | 2022/09 | 169
8.8.35 Command: Reset
The Reset command resets the read/write device and the interface. The input, output data and
the buffer are cleared.
See description of the output data, p. [}105].
Request
Loop counter See description of the output data
Command code 0x8000 (hex.), 32768 (dec.)
Read/write head address See description of the output data
Length UID/EPC Not required
Start address 0: Software reset
1: Voltage reset
Length Not required
Timeout See description of the output data
Write fragment No. 0
Read fragment No. See description of the output data
Write data Not required
See description of the input data, p. [}100].
Response
Loop counter See description of the input data
Response code 0x8000 (hex.), 32768 (dec.)
Length Not required
Error code See description of the input data
Tag in
detection range
See description of the input data
Data (bytes) available See description of the input data
Tag counter See description of the input data
Write fragment No. 0
Read fragment No. See description of the input data
Read data Not required