8.1.1 Meaning of the parameter bits
The default values of the firmware, the DTM and the EDS file are shown in bold. The default
values for PROFINET may vary.
Designation Meaning
Operation mode (OMRFID) 0: Deactivated
1: HF compact
2: HF extended
3: HF bus mode
4: UHF compact
5: UHF extended
Tag type (TAGTYPE)
0: Automatic HF tag detection
1: NXP Icode SLIX
2: Fujitsu MB89R118
3: TI Tag-it HF-I Plus
4: Infineon SRF55V02P
5: NXP Icode SLIX-S
6: Fujitsu MB89R119
7: TI Tag-it HF-I
8: Infineon SRF55V10P
9: Reserved
10: Reserved
11: NXP Icode SLIX-L
12: Fujitsu MB89R112
13: EM4233SLIC
Read/write heads with firmware from Vx.91 also support:
14: NXP SLIX2
15: TI Tag-it HFI Pro
16:Turck sensor tag
17: Infineon SRF55V02S
18: Infineon SRF55V10S
19: EM4233
20: EM4237
21: EM4237 SLIC
22: EM4237 SLIX
23: EM4033
Bypass time (BYPASS) Bypass time in ms, adjustable from 4…1020ms,
default setting: 200ms
HF: Automatic tuning of
read/write head (AT)
0: No (automatic tuning off)
1: Yes (automatic tuning on)
Termination active (TERM)
0: Yes (bus terminating resistor activated)
1: No (bus terminating resistor deactivated)
In HF bus mode the bus terminating resistor is activated by default.
HF: Heartbeat read/write head
(HB)
The device confirms its operational readiness with a signal sent at regular
intervals to the controller. NOTE: A heartbeat slows down the system since a
heartbeat and another command cannot be executed simultaneously.
0: No (heartbeat read/write head off)
1: Yes (heartbeat read/write head on)
HF: Multitag (ANTI)
0: No (multitag mode off)
1: Yes (multitag mode on)
Deactivate all Diags (DDI)
0: No (all diagnostic messages on)
1: Yes (all diagnostic messages off)