RFID channels — overview of commands
Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com
07.00 | 2022/09 | 141
Example: Direct command in UHF applications (set output power)
Read the set power from the RAM of the reader.
Request
Loop counter 0
Command code 0x0060
Read/write head address 0
Length UID/EPC 0
Start address 0
Length 5
Timeout 200
Write fragment No. 0
Read fragment No. 0
Write data 0x09 8A 4A 03 01
Change output power: Write "30 dBm" power to the reader's RAM and flash memory. The
sixth byte of the write data sets the power in dBm as a hexadecimal value.
Request
Loop counter 0
Command code 0x0060
Read/write head address 0
Length UID/EPC 0
Start address 0
Length 6
Timeout 200
Write fragment No. 0
Read fragment No. 0
Write data 0x09 8A 3C 03 01 1E