Operation
Use CODESYS function blocks
Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com
07.00 | 2022/09 | 237
Fig.145: Activate the FB_Extended function block (example: Ch0, read or write 128 bytes)
Fig.146: FB_Extended function block — overview of inputs and outputs
NOTE
When using function blocks, the UID is not automatically displayed in Idle mode. The
device does not have to be reset to Idle mode between two identical commands.
The FB_BusMode and FB_Compact function blocks must be connected in the same way as the
FB_Extended function block. Further information is provided in the documentation in the
CODESYS package.