EasyManuals Logo

turck TBEN-RFID Series User Manual

turck TBEN-RFID Series
288 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #28 background imageLoading...
Page #28 background image
Connection
Connecting RFID read/write devices
Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com
07.00 | 2022/09 | 28
Connecting read/write heads for HF bus mode in Ex areas
NOTE
Information on the maximum cable lengths in Ex areas is provided in the data sheets
of the connected read/write heads.
The following devices are required for bus mode in hazardous areas:
n TN-R42TC-EX/C53 read/write head (ID 100020167)
n TN-R42TC-EX/C65 read/write head (ID 100028462) with integrated bus terminating resistor
n …/S2500 RFID extension cables
n Operation in Zone 2/22:
VT2-FKM5-FKM5-FSM5 (ID 6930573) junction box for connecting several read/write
heads to an RFID port
SC-M12/3GD safety clip (ID 6900390)
Optional: VB2-FKM5-FSM5.205-FSM5.305/S2550 junction box (ID 6936821) for feeding
in an additional power supply
n Operation in Zone 1/21:
Ex-e terminal boxes
DANGER
Potentially explosive atmosphere
Risk of explosion due to spark ignition
Operation in Zone 2/22:
Only connect the read/write heads if there is no potentially explosive atmo-
sphere present or if the device is in a de-energized state.
Protect the M12 male connector against accidental removal during operation
using safety clip SC-M12/3GD.
Protect the M12 male connector against mechanical damage.
DANGER
Potentially explosive atmosphere
Risk of explosion due to spark ignition
When used in Zone 1/21, observe the instructions for use for the connected
devices.
Operation in Zone 2/22: Connect the read/write heads via VT2-FKM5-FKM5-FSM5 junc-
tion boxes as shown in the figure below (for max. tightening torque see the data sheet of
the cable used). The maximum length of the spur line is 2m.
Operation in Zone 1/21: Connect the read/write heads via terminal boxes as shown in the
figure below. The maximum length of the spur line is 2m.
Make allowance for the power supply, particularly at switch-on (see data sheet), as well as
the maximum current carrying capacity of the lines (4A).
Make allowance for the voltage drop on the line. When used in Zone 2/22, provide an ad-
ditional power supply between the read/write heads using junction box VB2-FKM5-
FSM5.205-FSM5.305/S2550 if necessary. Up to 20 read/write heads can be connected
without an additional power supply.
Use the TN-R42TC-EX/C65 read/write head with an integrated bus terminating resistor as
the last device. Do not connect a separate bus terminating resistor.

Table of Contents

Other manuals for turck TBEN-RFID Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the turck TBEN-RFID Series and is the answer not in the manual?

turck TBEN-RFID Series Specifications

General IconGeneral
Brandturck
ModelTBEN-RFID Series
CategoryRecording Equipment
LanguageEnglish

Related product manuals