B. Changing display language
Note! In this instruction is supposed, that the valid lan-
guage is english.
1. When the display shows the main menu, press NEXT
PAGE---button, until you find selection SYSTEM.
2. Press the SELECT---button, and you will see a page,
which has selections TEST INPUT, TEST OUTPUT, LAN-
GUAGE etc..
3. Move the highlighted area onto the LANGUAGE and
press SELECT---button, after which the display shows the
language menu. Move the highlighted area onto the desi-
red language and press the SELECT---button.
4. A new display language is valid.
C. Others
Before the FieldMaster is able to show for example flow
amount or area, the flow meter must be calibrated and
working width of an implement must be input. In the same
way must be calibrated extreme positions of possible posi-
tion potentiometer. When necessary, possible weight mea-
suring cell or manometer must also be calibrated. In addi-
tion, an amount of magnets for a measuring sensor affects
the measurement.