System Attributes (PGM 160/161/163) 1-69
Chapter 1: SBX IP Online PC Admin
SBX IP - PC Admin Guide
Clear ACD
Database
after Print
ON/OFF OFF Determines if ACD database initializes
after print-out.
VMIB Prompt
Gain
00-31 08 To control prompt gain level
VM with CLI
Info
ON/OFF OFF If the setting is ON, CLI is added when
Voice Mail information is printed through
RS232 port by SMDI.
ACD Print
Timer Unit
1: HOUR
0: SEC
SEC Determines the unit of ACD Print timer of
Flex Btn 10 (1 hour or 10 seconds)
Set VM SMDI
Type
TYPE II/
TYPE I
TYPE I Set VM SMDI type.
Incoming Toll
Check
ON/OFF OFF Enable or disable the toll check for
incoming calls
No DSS
Indication
ENABLE/
DISABLE
DISABLE Enable or disable the LED of the CO
button while ringing for incoming, transfer
and recalling. It is not applied for direct
ringing such as DID/DISA.
UK Billing
Mode
ON/OFF OFF If this value is set to ON, UK Billing Mode
is applied (UK only).
COS 7 When
Auth Fail
ON/OFF OFF If authorization is failed with PGM227,
COS will be COS 7 or not with this setting.
Auto Fax
Transfer CO
None, 1-36 None If Auto FAX CO line is programmed, the
system answers and detects the FAX
calling tone (1100Hz, 0.5sec ON/3sec
OFF repeat tone) from an incoming analog
CO line. The system will route this call to
the last SLT port on BKSU) when tone is
detected within programmed time.
5 Dgt Auth
Code Usage
ON/OFF OFF
System Attributes II (PGM161)
ITEM RANGE DEFAULT REMARK