Use the plastic shunts (actually contain metal for bridging two pins of jumper) for the
configurations. The possible settings are shown on the table as follows:
Fig. 4-5: without enclosure cover (top view)
Config. Sensor - Typ Drawing
Jumper setting
(see Fig. 4-4)
1
NPN-Sensor (settable/ 1 output)
detection: leading edge
BC DE GH IJ KL
2
NPN-Sensor (settable/ 1 output)
detection: trailing edge
BC DE GH IJ LF
3
PNP-Sensor (settable/ 1 output)
detection: leading edge
AB CD GH IJ KL
4
PNP-Sensor (settable/ 1 output)
detection: trailing edge
AB CD GH IJ LF
5
NPN-Sensor (antivalent/ 2 outputs)
detection: leading edge
BC DE GH
NPN-Sensor (antivalent/ 2 outputs)
detection: trailing edge
6
NPN-Sensor (bipolar)
detection: *changeable on sensor
BC DE HI
PNP-Sensor (bipolar)
detection: *changeable on sensor
7
PNP-Sensor (antivalent/ 2 outputs)
detection: leading edge
AB CD GH
8
PNP-Sensor (antivalent/ 2 outputs)
detection: trailing edge
AB CD HI
* The mode „leading edge“ or „trailing edge“ is set via button on the sensor itself and not with
jumper inside the controller.