Code
[0921]
(cont'd)
[0922]
[0926]
[0955]
Description
Next/Previous -
Pressing these buttons
affects the Duty Cycle
value in Tests 2 and 3,
and changes Vhigh in
[0921-2],
When running Tests 2
and 3, pressing the Enter
button copies the current
duty cycle value to NVM.
This code disables toner
faults so that the printer
will continue to operate.
While in Diagnostics,
enter the code [0922] and
select [Yes] for running
with toner faults. Enter
the code [0361] to exit
the diagnostic mode.
Resets the Toner Control
Bias to default value
IOT Internal Test Pattern
Print
9 test patterns are
available. The following
parameters can be
selected:
Paper source (roll)
Length of print
Print quantity
Folder program (if
folder is available)
Value
Code
[1004]
Description
Fuser Run Temperature
Display. This code
switches the fuser heat
rod on and increases the
fuser heat roll
temperature to the run
temperature. The run
temperature is displayed
in degrees (F) and
degrees (C). At run
temperature, the
Drum/Developer and
Fuser Drive Motors are
switched on. The
following conditions may
exist when the message
FUSER CAN NOT BE
TURNED ON,
CONDITION XX is
displayed:
03 Developer Cover is
open.
04 Cutter Cover is open
05 Xerographic Interlock
is open.
06 Right side door is
open.
07 Document Handler
interlock is open.
08 Fuser status problem.
Turn power off and try
again.
09 Illumination status
problem. Turn power
off and try again.
Value
Code
[1006]
[1010]
[1026]
[1030]
[1031]
[1035]
[10-36]
Description
Display Fuser
Temperature (Analog)
Fuser Scorch Sensor
(Thermistor RT2)
1 = Fuser temperature
less than or equal to
420* F (215
#
C)
0 = Fuser temperature
greater than 420' F
(215 C)
NOTE: Power must be
switched OFF then ON, in
order to reset signal.
Reset the Fuser Control
NVM to default values.
Reset Oil Web.
Resets the web counter
when & new web has
been instated.
Specify Oil Web Position.
Used if the NVM fails or is
reset. This sets the
controls for web use.
(Enter the diameter of the
supply spool in
millimeters.)
Disable LL-12 Fault
Detection (Drum Stall)
Value
Diagnostics
1/98
6-8
8830