Left To Right Stitch Alignment
(Figure 7): Selecting stitch Alignment displays the Left to Right Stitch Alignment screen.
This test evaluates the left to right stitch alignment of the three cameras and makes an auto-
matic electronic adjustment If required. Go to ADJ 4.4.7 in Section 4 of this service manual for
detailed Instructions on this adjustment.
Front to Back Stitch Alignment
(Figure 8): This test evaluates the front to back stitch alignment of the three cameras. If the
alignment is not correct, a mechanical adjustment must be made. Go to ADJ 4.4.6 in Section 4
of this service manual for detailed instructions on this adjustment.
08O00I2A-WHO
08WI1CA-WHa
Figure 7. Left to Right Stitch Alignment Screen
Figure 8 . Front to Back Stitch Alignment Screen
8830 DDS
3/98
6-7
General Procedures
Diagnostics