9. (Figure 9): Connect the following scanner cables to the 8830 Controller Connector Panel.
A
Attach Power
Cable (from 8830
DDS Control
Panel)
C.
Connect SCSI
cable (from
scanner)
Attach Ul Data cable
to right of Power
Cable connector
Network Interface Card
connection (optional)
Figure 9 Location of Control Panel Cable connection on 8830 Controller
NOTE: Unless the following power-on sequence Is followed, the scanner Control Panel
will not illuminate, and the 8830 DDS system will not function correctly.
10. Power on the 8830 DDS system by performing the following steps:
a. Power on the 7356 scanner.
b. Power on the 8830 Controller.
c. Power on the 8830 Printer.
NOTE: If needed, the 8830 DDS Control Panel ambient intensity can be adjusted by
rotating the trim pot on the Scanner Control Panel Main PWB. A small jeweler's
screwdriver will be required to make this adjustment.
11. Make a test print.
12. Perform the scanner Functional Checks from Section 4 of this service manual.
a. Left to Right Stitch Alignment (ADJ 4.4.7).
b. Front to Back Stitch Alignment. (ADJ 4.4.6).
c. Check / Adjust System Image Quality by performing ADJ 4.4.5 System Image Qual-
ity.
13. Make a copy of the 82E5980 Test Pattern and check the overall copy Quality.
NOTE: In the following steps, the term "assist" Indicates that the customer performs the
actual tasks, under supervision of the Customer Service Engineer.
NOTE: Prior arrangement for availability, configuration, and location of the PC must be
documented on the XES GOLD configuration sheet.
NOTE: Ka customer PC is not available on site, the CSE will make arrangements to have
a District Laptop available to test and demonstrate to the customer the functionality of the
8830 connectivity of the following:
• Win RTL - Serial and Parallel ports
• PMT- Serial and Network ports
• DMT' Parallel and Network ports
• VPI • Serveware only
• Host SCSI - Serveware only
14. If the 8830 DDS system Is being connected to a network, refer to the 8830 Controller Ser-
vice Manual, Otherwise, perform the following:
a. With the assistance of a customer analyst, connect the system to a customer Host
PC.
b. Inform the customer of the available software for the 8830 Controller.
c. Connect the Host Cable to the appropriate connector on the 8830 Controller Con-
nector Panel.
15. Complete customer operator training per customer training checklist.
16. Contact Work Support to complete installation in FWSS.
General Procedures
8830 DOS Installation