156
2) Operands
Operands
Function
Data Type
S
Source soft element address
2 bits, HEX
D
Target soft element address
ASCII code
n
Transform character quantity
16 bits, BIN
3)Suitable soft components
Operands
Word soft elements
Bit soft elements
System
Constant
Module
System
D
FD
TD
CD
DX
DY
DM
DS
K/H
ID
QD
X
Y
M
S
T
C
Dn.m
S
D
n
*Notes: D includes D, HD; TD includes TD, HTD; CD includes CD, HCD, HSCD, HSD; DM
includes DM, DHM; DS includes DS, DHS. M includes M, HM, SM; S includes S, HS; T
includes T, HT; C includes C, HC.
ASCI D100 D200 K4
n
X0
D transform the source Hex data to ASCII code, and store in S . The transformation chacters
are n.
D will store one ASCII code.
The convert process is this
n
D
K1
K2
K3
K4
K5
K6
K7
K8
K9
D200 down
[C]
[B]
[A]
[0]
[4]
[3]
[2]
[1]
[8]
D200 up
[C]
[B]
[A]
[0]
[4]
[3]
[2]
[1]
D201 down
[C]
[B]
[A]
[0]
[4]
[3]
[2]
D201 up
[C]
[B]
[A]
[0]
[4]
[3]
D202 down
[C]
[B]
[A]
[0]
[4]
D202 up
[C]
[B]
[A]
[0]
D203 down
[C]
[B]
[A]
D203 up
[C]
[B]
D204 down
[C]
Description
Assign start device:
(D100)=0ABCH
(D101)=1234H
(D102)=5678H
[0]=30H [1]=31H
[5]=35H [A]=41H
[2]=32H [6]=36H
[B]=42H [3]=33H
[7]=37H [C]=43H
[4]=34H [8]=38H
tudonghoatoancau.com

Table of Contents

Other manuals for Xinje XD Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Xinje XD Series and is the answer not in the manual?

Xinje XD Series Specifications

General IconGeneral
Input Voltage24V DC
Storage Temperature-20°C to 70°C
Protection ClassIP20
TypePLC
SeriesXD
Programming LanguageLadder Logic, Instruction List
Communication InterfaceRS232, RS485
Power Supply24V DC
Digital InputsAvailable (number varies by model)
Digital OutputsAvailable (number varies by model)
Analog InputsAvailable (number varies by model)
Analog OutputsAvailable (number varies by model)
Output TypeRelay, Transistor
Number of InputsVaries by model (see Digital Inputs and Analog Inputs)
Number of OutputsVaries by model (see Digital Outputs and Analog Outputs)
Operating Temperature0°C to 50°C
Humidity5% to 95% (non-condensing)