EasyManuals Logo

Xinje XD Series User Manual

Xinje XD Series
456 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #213 background imageLoading...
Page #213 background image
212
requirement
requirement
2)Operands
Operands
Function
Type
S
Specify HSC code (Eg. HSC0)
32 bits, BIN
D
Specify the comparison value (Eg. K100, D0)
32 bits, BIN
3)Suitable Soft Components
Operands
Word soft elements
Bit soft elements
System
Constant
Module
System
D
FD
TD
CD
DX
DY
DM
DS
K/H
ID
QD
X
Y
M
S
T
C
Dn.m
S1
Only can be HSC
S2
*Notes: D includes D, HD; TD includes TD, HTD; CD includes CD, HCD, HSCD, HSD;
DM includes DM, DHM; DS includes DS, DHS. M includes M,HM,SMS includes S,HS
T includes T,HTC includes C, HC.
When M0 is on, HSC0 counts X0, X1 signal in AB phase mode, compares the high-speed
counting value with the value set in register D20. When the high-speed counting value is
equal to the set value, HSC0 coil is set on immediately, and the counting value is
accumulated in HSCD0 (double words).
If the driving condition M0 is not disconnected, HSC0 will remain on state and continue
counting, and the counting value in HSCD0 will continue to accumulate.
If the driving condition M0 is disconnected, HSC0 will remain on state and the counting
value in HSCD0 will remain unchanged.
During the counting process, if M0 is disconnected and connected again, the values in
HSCD0 will continue to accumulate after the last counting value.
In the counting process, if the setting value in D20 changes and the current counting value
is less than the new setting value, then the new setting value is compared.
5-7-3 HSC reset [RST]
The reset mode of high-speed counter is software reset mode.
FUNCTIONS AND ACTIONS
tudonghoatoancau.com

Table of Contents

Other manuals for Xinje XD Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Xinje XD Series and is the answer not in the manual?

Xinje XD Series Specifications

General IconGeneral
Input Voltage24V DC
Storage Temperature-20°C to 70°C
Protection ClassIP20
TypePLC
SeriesXD
Programming LanguageLadder Logic, Instruction List
Communication InterfaceRS232, RS485
Power Supply24V DC
Digital InputsAvailable (number varies by model)
Digital OutputsAvailable (number varies by model)
Analog InputsAvailable (number varies by model)
Analog OutputsAvailable (number varies by model)
Output TypeRelay, Transistor
Number of InputsVaries by model (see Digital Inputs and Analog Inputs)
Number of OutputsVaries by model (see Digital Outputs and Analog Outputs)
Operating Temperature0°C to 50°C
Humidity5% to 95% (non-condensing)