210
doubling
4
4 frequency doubling
SFD322
HSC4 frequency
doubling
2
2 frequency doubling
4
4 frequency doubling
SFD323
HSC6 frequency
doubling
2
2 frequency doubling
4
4 frequency doubling
SFD324
HSC8 frequency
doubling
2
2 frequency doubling
4
4 frequency doubling
SFD325
HSC10 frequency
doubling
2
2 frequency doubling
4
4 frequency doubling
SFD326
HSC12 frequency
doubling
2
2 frequency doubling
4
4 frequency doubling
SFD327
HSC14 frequency
doubling
2
2 frequency doubling
4
4 frequency doubling
SFD328
HSC16 frequency
doubling
2
2 frequency doubling
4
4 frequency doubling
SFD329
HSC18 frequency
doubling
2
2 frequency doubling
4
4 frequency doubling
Note: After the SFD register is modified, it is necessary to restart the high-speed counter
(i.e. disconnect and reboot the drive condition) in order to make the new configuration
effective!
5-7 HSC instruction
This section introduces the usage of single-phase high-speed counting instruction (CNT), AB-
phase high-speed counting instruction (CNT_AB), reset of high-speed counting, reading and
writing of high-speed counting.
5-7-1 Single phase HSC [CNT]
1)Instruction Summary
Single phase HSC instruction
Single phase HSC [CNT]
16 bits Instruction
-
32 bits Instruction
CNT
Execution condition
Normally ON/OFF
coil
Suitable models
XD, XL(exclude
XD1 / XL1 )
Hardware requirement
-
Software
requirement
-
2)Operands
Operands
Function
Type
S
Specify HSC code (Eg. HSC0)
32 bits, BIN
D
Specify comparison value (Eg. K100, D0)
32 bits, BIN
tudonghoatoancau.com

Table of Contents

Other manuals for Xinje XD Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Xinje XD Series and is the answer not in the manual?

Xinje XD Series Specifications

General IconGeneral
Input Voltage24V DC
Storage Temperature-20°C to 70°C
Protection ClassIP20
TypePLC
SeriesXD
Programming LanguageLadder Logic, Instruction List
Communication InterfaceRS232, RS485
Power Supply24V DC
Digital InputsAvailable (number varies by model)
Digital OutputsAvailable (number varies by model)
Analog InputsAvailable (number varies by model)
Analog OutputsAvailable (number varies by model)
Output TypeRelay, Transistor
Number of InputsVaries by model (see Digital Inputs and Analog Inputs)
Number of OutputsVaries by model (see Digital Outputs and Analog Outputs)
Operating Temperature0°C to 50°C
Humidity5% to 95% (non-condensing)