EasyManuals Logo

Xinje XD Series User Manual

Xinje XD Series
456 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #299 background imageLoading...
Page #299 background image
298
6-5-3 Serial port parameter name and setting
Assuming that HD0-HD14 corresponds to serial port parameters, the parameter names and
settings represented by registers are shown in the table below.
Para
meter
addre
ss
Parameter name and settings
MODBUScom
munication(HD
0=1)
Free
communication
(HD0=2)
X-NET communication
Ethernet
communication(
HD0=3)
OMMS
(HD0=3)
TBN
(HD0=3)
HD0
Network type
1: MODBUS; 2: free ; 3: X-NET; 4: MODBU-TCP
HD1
MODBUS
station no.
1~254
Baud rate refer
to table 1
Net ID
0~32767
Net ID
0~32767
Net ID
IP address high
2-byte
HD2
Transmission
mode
0: RTU
128: ASCII
Frame format
refer to table 2
Station no.
0~100
Station no.
0~100
Station no.
IP address low
2-byte
HD3
Baud rate refer
to table 1
Free properties
bit7:
1: with start
character
0: no start
character
bit6
1: with end
character
0: no end
character
Physical layer type
1: PHY_RS485
2: PHY_SOF(Unidirectional Fiber Ring Network)
3: PHY_OFPP(Optical Fiber Point Network)
4: PHY_RS232
5: PHY_RS422
6: PHY_TTL (TTLvoltage network)
HD4
Frame format
refer to table 2
Start character
Link Layer Type
0: TBN
1: HDN
2: CCN
3: PPFD
4: PPU
5: Ethernet
HD5
retry count
0~5
End character
OMMS
properties
128: Supports
periodic
communication,
otherwise does
not support
Baud rate
refer to table
1
Subnet mask
high 2-byte
HD6
Reply timeout
0~65535
Frame timeout
0~255
OMMS baud
rate refer to
table 1
Token Cycle
Time
1~60000(ms)
Subnet mask
low 2-byte
HD7
Delay before
sending
0~255
Reply timeout
0~65535 (0 is
infinite wait)
OMMS slave
station list
Each bit of each
byte in the array
indicates whether
the slave station
is accessible (the
master station is
valid, i.e. the
Max station
number
1~100
Gateway
address high 2-
byte
tudonghoatoancau.com

Table of Contents

Other manuals for Xinje XD Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Xinje XD Series and is the answer not in the manual?

Xinje XD Series Specifications

General IconGeneral
Input Voltage24V DC
Storage Temperature-20°C to 70°C
Protection ClassIP20
TypePLC
SeriesXD
Programming LanguageLadder Logic, Instruction List
Communication InterfaceRS232, RS485
Power Supply24V DC
Digital InputsAvailable (number varies by model)
Digital OutputsAvailable (number varies by model)
Analog InputsAvailable (number varies by model)
Analog OutputsAvailable (number varies by model)
Output TypeRelay, Transistor
Number of InputsVaries by model (see Digital Inputs and Analog Inputs)
Number of OutputsVaries by model (see Digital Outputs and Analog Outputs)
Operating Temperature0°C to 50°C
Humidity5% to 95% (non-condensing)