EasyManuals Logo

Xinje XD Series User Manual

Xinje XD Series
456 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #129 background imageLoading...
Page #129 background image
128
Note: When the edge instruction is triggered, the automatic addition and subtraction operation
is performed for each trigger. If it is triggered by normally open/normally closed, the
operation of auto-addition and auto-subtraction will be performed in each scanning period
after the conduction.
4-6-6 Mean [MEAN, DMEAN]
1)Summary
Get the mean value of data
Mean [MEAN,DMEAN]
16 bits
MEAN
32 bits
DMEAN
Execution
condition
Normally ON/OFF,
rising/falling edge
Suitable
Models
XD, XL
Hardware
requirement
-
Software
requirement
-
2)Operands
Operands
Function
Data Type
S
The source datastart address
16 bits/32 bits, BIN
D
The mean result address
16 bits/32 bits, BIN
n
The data quantity
16 bits/32 bits, BIN
3)Suitable soft components
Operan
ds
Word soft elements
Bit soft elements
System
Consta
nt
Modul
e
System
D
F
D
T
D
C
D
D
X
D
Y
D
M
D
S
K/H
I
D
Q
D
X
Y
M
S
T
C
Dn.
m
S
D
n
*Notes: D includes D, HD; TD includes TD, HTD; CD includes CD, HCD, HSCD, HSD;
DM includes DM, DHM; DS includes DS, DHS. M includes M,HM,SMS includes S,HS
T includes T,HTC includes C, HC.
(D0) + +
3
(D10)
(D1) (D2)
Store the mean value of source data (source sum divide by source quantity n). give the
remainder .
The n cannot larger than soft component quantity, otherwise there will be error.
Description
MEAN D0 D10 K3
X0
n
tudonghoatoancau.com

Table of Contents

Other manuals for Xinje XD Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Xinje XD Series and is the answer not in the manual?

Xinje XD Series Specifications

General IconGeneral
Input Voltage24V DC
Storage Temperature-20°C to 70°C
Protection ClassIP20
TypePLC
SeriesXD
Programming LanguageLadder Logic, Instruction List
Communication InterfaceRS232, RS485
Power Supply24V DC
Digital InputsAvailable (number varies by model)
Digital OutputsAvailable (number varies by model)
Analog InputsAvailable (number varies by model)
Analog OutputsAvailable (number varies by model)
Output TypeRelay, Transistor
Number of InputsVaries by model (see Digital Inputs and Analog Inputs)
Number of OutputsVaries by model (see Digital Outputs and Analog Outputs)
Operating Temperature0°C to 50°C
Humidity5% to 95% (non-condensing)